Product Introduction:
A water air heat exchanger is a product that operates without a compressor, consisting of a specially designed water air heat exchanger, centrifugal fan, solenoid valve, and integrated temperature control system. This series of products belongs to the water-cooled type, requiring cooling water to cool down, with low cost and high refrigeration efficiency. The product adopts advanced design concepts in the unit design and is suitable for industries such as steel plants, coking plants with high ambient temperatures, and textile industries with high dust and oil pollution.
Application areas:
CNC system electrical control cabinet, CNC machining machine tool power cabinet, machine tool equipment, power control cabinet, distribution cabinet, mechanical automation electrical box, various measuring instruments.
Product features:
1. Independent internal and external sealed air circulation to prevent dust, oil mist, and moisture from entering the interior of the electrical box;
2. By adjusting the inlet water temperature, the temperature and humidity inside the electrical box can be effectively controlled to prevent electrical component failure;
3. Compact structure, small volume, easy installation and maintenance;
4. Special components are treated with special materials or special methods, which have excellent corrosion resistance and sealing performance;
5. Reliable performance, smooth operation, low noise, and high energy efficiency;
6. Adopting high-voltage electrostatic spraying treatment for anti-static and beautiful appearance;
7. No refrigerant, low power consumption, very energy-efficient;
Technical parameters:
*Input voltage: AC220V/50Hz *Operating temperature range:- 5℃~65℃
Installation method:
Installation location: external or door mounted.
① Select a suitable side on all sides of the electrical cabinet;
② According to the "opening size diagram", open the corresponding air inlet and outlet, wiring port, and installation hole on the side;
③ The air conditioner should be perpendicular to the ground and not tilted to avoid affecting the normal discharge of condensed water;
④ Once the air conditioner is fixed and connected to the power supply, it can be put into use;
For product inquiries/technical inquiries/obtaining electronic sample books/specification sheets, please contact: 400-881-5289